SKU -
Protect walls from firearm threats with UL 752 bullet resistant wall panels from Liberty Shielding. Our ballistic fiberglass panels provide tested ballistic protection while remaining thin enough to conceal behind drywall, wood panels, millwork, and other architectural finishes.
Manufactured from layers of woven fiberglass reinforcement bonded with high-strength resin, these bullet resistant fiberglass panels are designed to absorb and disperse ballistic energy while minimizing dangerous ricochet and spall.
Available for online ordering in UL 752 Level 3 and Level 8 configurations, these 4' x 8' ballistic panels can be incorporated into new construction or used to upgrade existing walls in commercial, institutional, government, and high-security facilities.
Select your required UL 752 protection level and quantity above to see your price and order online.
Our standard UL 752 Level 3 bullet resistant fiberglass panel provides protection against the specified handgun threats associated with Level 3, including .44 Magnum.
Level 3 is commonly specified where protection against handgun threats is required.
For applications requiring protection against higher-powered rifle threats, Liberty Shielding offers UL 752 Level 8 wall protection using three layers of our Level 3 ballistic fiberglass panels.
The Level 8 system is supplied as individual 1/2" layers rather than a single 504-pound panel, making transportation and installation considerably more manageable.
Bullet resistant fiberglass, also called ballistic fiberglass, is a composite material manufactured from multiple layers of woven glass fibers bonded together with high-strength resin.
When struck by a projectile, the layered composite is designed to absorb and disperse the projectile's energy through the material rather than relying on a hard surface to deflect it.
This construction provides several advantages for building applications:
The result is a practical way to add ballistic protection to walls without leaving the protective material exposed.
Typical interior construction materials should not be assumed to provide reliable ballistic protection. Conventional drywall, plywood, wood framing, and other standard building materials are not substitutes for a tested ballistic barrier.
Ballistic fiberglass panels can be installed within the wall assembly and concealed behind the finished surface, allowing architects, contractors, and building owners to add ballistic protection without changing the finished appearance of the room.
Depending on the wall design, panels can be incorporated behind:
This makes ballistic fiberglass particularly useful for projects where security is required but the finished space should still look like a conventional commercial interior.
Our UL 752 ballistic wall panels are used in facilities where employees, occupants, customers, or critical infrastructure require increased protection from firearm threats.
Common applications include:
People frequently search for “bulletproof drywall,” “ballistic drywall,” or “bullet resistant drywall,” but conventional gypsum drywall itself is not designed to provide certified ballistic protection.
A more practical approach is to install UL 752 ballistic fiberglass panels behind the drywall.
The fiberglass provides the ballistic barrier while the drywall provides the normal finished wall surface.
This creates a wall that can look virtually identical to conventional construction while incorporating tested ballistic protection behind the finished surface.
The terms “bulletproof wall panels” and “bulletproof fiberglass” are commonly used when searching for ballistic building materials, but bullet resistant is the more accurate terminology.
Ballistic panels are tested against specific firearm and ammunition threats. No building material should be assumed to stop every possible ballistic threat.
Selecting the appropriate UL 752 protection level is therefore an important part of designing a ballistic wall system.
The appropriate ballistic protection depends on the threats identified for the facility.
UL 752 Level 3 is intended for the standard's specified handgun threat and is commonly used where protection from handguns is the primary concern.
UL 752 Level 8 addresses a substantially higher-energy rifle threat represented by the standard's specified 7.62mm x 51 (.308) ammunition.
Because Level 8 requires substantially more material, the finished system is thicker and heavier than Level 3.
Project security requirements should determine the appropriate protection level rather than simply selecting the highest available rating.
One of the major advantages of ballistic fiberglass panels is their ability to be fabricated in the field using conventional construction methods.
Panels can be cut as required to accommodate the dimensions and layout of the protected wall.
Ballistic wall systems should be installed so that the protective barrier remains continuous throughout the required protected area.
Particular attention should be given to:
Any unprotected opening or penetration can create a weak point in an otherwise protected wall.
Where complete ballistic protection is required, doors, windows, frames, transaction openings, and other components should provide protection appropriate for the specified ballistic threat.
Security projects don't always have the luxury of long manufacturing lead times.
Our standard UL 752 Level 3 ballistic fiberglass panels are typically ready to ship within 2–3 business days after order placement, allowing contractors and facilities to obtain ballistic wall materials quickly.
Level 8 systems use multiple layers of Level 3 panels, allowing the individual sheets to remain manageable during transportation and installation.
Our standard ballistic fiberglass sheets measure 48" x 96" (4' x 8').
A 4' x 8' UL 752 Level 3 panel weighs approximately 168 pounds, or approximately 5.25 pounds per square foot.
Our Level 3 panel is 1/2" thick.
Our Level 8 wall system uses three layers of the 1/2" ballistic panels, creating a total nominal thickness of approximately 1-1/2".
Yes. The panels are field cuttable, allowing installers to fabricate panels as required for the wall layout.
Yes. This is one of their primary applications. The ballistic fiberglass can be installed as part of the wall assembly and concealed behind conventional drywall or other architectural finishes.
“Bulletproof drywall” is a commonly searched term, but standard gypsum drywall should not be considered bullet resistant. UL 752 ballistic fiberglass installed behind the drywall provides the ballistic barrier while allowing the wall to retain a conventional finished appearance.
The materials behave differently and each can be appropriate for particular applications. Ballistic fiberglass offers several advantages for interior construction, including field fabrication, corrosion resistance, relatively thin construction, and reduced ricochet compared with hard ballistic materials.
UL 752 Level 3 addresses the standard's specified .44 Magnum handgun threat, while Level 8 addresses a significantly higher-energy 7.62mm x 51 (.308) rifle threat. Level 8 therefore requires substantially more ballistic material.
Standard Level 3 panels are typically ready to ship within 2–3 business days after the order is placed.
Customer is responsible for unloading all freight shipments. Each Level 3 4' x 8' ballistic panel weighs approximately 168 pounds, so appropriate unloading equipment and personnel must be arranged before delivery.
Prior to delivery, you must arrange for a forklift, loading dock, or other suitable equipment and personnel capable of safely unloading the shipment. Freight carriers are not responsible for unloading material from the truck unless a specific unloading service has been arranged in advance.
Failure to have the proper equipment, personnel, or facilities available to receive and unload the shipment is not grounds for refusing delivery, cancellation, or return.
The customer is responsible for any additional charges resulting from re-delivery, missed delivery attempts, storage, detention, or changes to the delivery address after the order has shipped.
By placing and proceeding with an order, the customer acknowledges and accepts these delivery requirements and agrees to the Liberty Shielding Terms & Conditions available at:
https://shop.libertyshielding.com/terms-and-conditions/
Order UL 752 bullet resistant fiberglass wall panels directly from Liberty Shielding for commercial, institutional, government, and residential security applications.
Choose your required UL 752 Level 3 or Level 8 protection, select the quantity needed for your project, and add the panels directly to your cart.
Standard Level 3 panels measure 4' x 8', are 1/2" thick, weigh approximately 168 pounds each, and are typically ready to ship within 2–3 business days.
Select your protection level and quantity above to see your price and order online.